Monitoring Interfaces and Transceivers with ethtool
The ethtool
command enables you to query or control the network driver and hardware settings and takes the device name, such as swp1, as an argument. When the device name is the only argument, ethtool
prints the network device settings. See man ethtool(8)
for details.
NVIDIA recommends using the l1-show
command to monitor Ethernet data; refer to Troubleshoot Layer 1.
Monitor Interface Status
To check the status of an interface, run the ethtool <interface>
command:
cumulus@switch:~$ ethtool swp1
Settings for swp1:
Supported ports: [ FIBRE ]
Supported link modes: 1000baseT/Full
10000baseT/Full
Supported pause frame use: No
Supports auto-negotiation: No
Advertised link modes: 1000baseT/Full
Advertised pause frame use: No
Advertised auto-negotiation: No
Speed: 10000Mb/s
Duplex: Full
Port: FIBRE
PHYAD: 0
Transceiver: external
Auto-negotiation: off
Current message level: 0x00000000 (0)
Link detected: yes
The switch hardware includes the active port settings. The output of ethtool <interface>
shows the port settings in the kernel. The switchd
process keeps the hardware and kernel in sync for the important port settings (speed, auto-negotiation, and link detected). However, some fields in ethtool
, such as Supported Link Modes and Advertised Link Modes, do not update based on the actual module in the port and might show incorrect or misleading results.
To query interface statistics, run the ethtool -S <interface>
command:
cumulus@switch:~$ ethtool -S swp1
NIC statistics:
rx_queue_0_packets: 5
rx_queue_0_bytes: 300
rx_queue_0_drops: 0
rx_queue_0_xdp_packets: 0
rx_queue_0_xdp_tx: 0
rx_queue_0_xdp_redirects: 0
rx_queue_0_xdp_drops: 0
rx_queue_0_kicks: 1
tx_queue_0_packets: 144957
tx_queue_0_bytes: 10546468
tx_queue_0_xdp_tx: 0
tx_queue_0_xdp_tx_drops: 0
tx_queue_0_kicks: 144950
View and Clear Interface Counters
Interface counters provide information about an interface. You can view this information when you run cl-netstat
, ifconfig
, or cat /proc/net/dev
. You can also run sudo cl-netstat -c
to save or clear the interface counters.
cumulus@switch:~$ sudo cl-netstat
Kernel Interface table
Iface MTU RX_OK RX_ERR RX_DRP RX_OVR TX_OK TX_ERR TX_DRP TX_OVR Flg
------------- ----- ------- -------- -------- -------- ------- -------- -------- -------- -----
lo 65536 185932 0 0 0 185932 0 0 0 LRU
eth0 1500 151883 0 0 0 13504 0 0 0 BMRU
swp1 9216 5 0 5 0 144986 0 0 0 BMsRU
swp2 9216 5 0 5 0 144988 0 0 0 BMsRU
swp3 9216 5 0 5 0 144944 0 0 0 BMsRU
swp49 9216 502662 0 5 0 502629 0 0 0 BMsRU
swp50 9216 507636 0 5 0 507666 0 0 0 BMsRU
swp51 9216 749122 0 5 0 794080 0 0 0 BMRU
swp52 9216 216057 0 5 0 212567 0 0 0 BMRU
bond1 9216 0 0 0 0 144942 0 0 0 BMmRU
bond2 9216 0 0 0 0 144944 0 0 0 BMmRU
bond3 9216 0 0 0 0 144944 0 0 0 BMmRU
br_default 9216 5072 0 0 0 5074 0 0 0 BMRU
mgmt 65575 3365 0 0 0 0 0 936 0 OmRU
peerlink 9216 1010288 0 0 0 1010295 0 0 0 BMmRU
peerlink.4094 9216 506672 0 0 0 506668 0 0 0 BMRU
vlan10 9216 1687 0 0 0 1687 0 0 0 BMRU
vlan10-v0 9216 1678 0 0 0 1677 0 0 0 BMRU
vlan20 9216 1688 0 0 0 1688 0 0 0 BMRU
vlan20-v0 9216 1678 0 0 0 1677 0 0 0 BMRU
vlan30 9216 1687 0 0 0 1689 0 0 0 BMRU
vlan30-v0 9216 1678 0 0 0 1678 0 0 0 BMRU
cumulus@switch:~$ sudo cl-netstat -c
Cleared counters
To see the cl-netstat
command options, run the cl-netstat -h
command.
Some services, such as MLAG and DHCP can cause drop counters to increment as expected and do not cause a problem on the switch.
Monitor Switch Port SFP and QSFP Hardware Information
To see hardware capabilities and measurement information on the SFP or QSFP module in a particular port, use the ethtool -m
command. If the SFP or QSFP supports Digital Optical Monitoring (the Optical diagnostics support
field is Yes in the output below), the optical power levels and thresholds also show below the standard hardware details.
In the sample output below, you can see that this module is a 1000BASE-SX short-range optical module, manufactured by JDSU, part number PLRXPL-VI-S24-22. The second half of the output displays the current readings of the Tx
power levels (Laser output power
) and Rx power (Receiver signal average optical power
), temperature, voltage and alarm threshold settings.
cumulus@switch$ ethtool -m swp3
Identifier : 0x03 (SFP)
Extended identifier : 0x04 (GBIC/SFP defined by 2-wire interface ID)
Connector : 0x07 (LC)
Transceiver codes : 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x05
Transceiver type : Ethernet: 1000BASE-SX
Transceiver type : FC: intermediate distance (I)
Transceiver type : FC: Shortwave laser w/o OFC (SN)
Transceiver type : FC: Multimode, 62.5um (M6)
Transceiver type : FC: Multimode, 50um (M5)
Transceiver type : FC: 200 MBytes/sec
Transceiver type : FC: 100 MBytes/sec
Encoding : 0x01 (8B/10B)
BR, Nominal : 2100MBd
Rate identifier : 0x00 (unspecified)
Length (SMF,km) : 0km
Length (SMF) : 0m
Length (50um) : 300m
Length (62.5um) : 150m
Length (Copper) : 0m
Length (OM3) : 0m
Laser wavelength : 850nm
Vendor name : JDSU
Vendor OUI : 00:01:9c
Vendor PN : PLRXPL-VI-S24-22
Vendor rev : 1
Optical diagnostics support : Yes
Laser bias current : 21.348 mA
Laser output power : 0.3186 mW / -4.97 dBm
Receiver signal average optical power : 0.3195 mW / -4.96 dBm
Module temperature : 41.70 degrees C / 107.05 degrees F
Module voltage : 3.2947 V
Alarm/warning flags implemented : Yes
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser output power high alarm : Off
Laser output power low alarm : Off
Laser output power high warning : Off
Laser output power low warning : Off
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Laser rx power high alarm : Off
Laser rx power low alarm : Off
Laser rx power high warning : Off
Laser rx power low warning : Off
Laser bias current high alarm threshold : 10.000 mA
Laser bias current low alarm threshold : 1.000 mA
Laser bias current high warning threshold : 9.000 mA
Laser bias current low warning threshold : 2.000 mA
Laser output power high alarm threshold : 0.8000 mW / -0.97 dBm
Laser output power low alarm threshold : 0.1000 mW / -10.00 dBm
Laser output power high warning threshold : 0.6000 mW / -2.22 dBm
Laser output power low warning threshold : 0.2000 mW / -6.99 dBm
Module temperature high alarm threshold : 90.00 degrees C / 194.00 degrees F
Module temperature low alarm threshold : -40.00 degrees C / -40.00 degrees F
Module temperature high warning threshold : 85.00 degrees C / 185.00 degrees F
Module temperature low warning threshold : -40.00 degrees C / -40.00 degrees F
Module voltage high alarm threshold : 4.0000 V
Module voltage low alarm threshold : 0.0000 V
Module voltage high warning threshold : 3.6450 V
Module voltage low warning threshold : 2.9550 V
Laser rx power high alarm threshold : 1.6000 mW / 2.04 dBm
Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm
Laser rx power high warning threshold : 1.0000 mW / 0.00 dBm
Laser rx power low warning threshold : 0.0200 mW / -16.99 dBm