Synchronous Ethernet - SyncE
SyncE is an ITU-T standard for transmitting clock signals over the Ethernet physical layer to synchronize clocks across the network by propagating frequency using the transmission rate of symbols in the network. A dedicated channel, ESMC manages this synchronization, as specified by the ITU-T Rec. G.8264 standard.
The Cumulus Linux switch includes a SyncE controller and a SyncE daemon.
- The SyncE controller reads performance counters to calculate the differences between transmit and receive ethernet symbols on the physical layer to fine tune the clock frequency.
- The SyncE daemon (
synced
):
Cumulus Linux constructs the SyncE clock identity as follows:
- The higher order 3 bytes are from the higher order 3 bytes (OUI) of the base MAC address.
- The middle 2 bytes are 0xff 0xfe.
- The lower order 3 bytes are from the lower order 3 bytes of the base MAC address.
- Only the NVIDIA SN3750-SX switch and the NVIDIA SN5400 switch support SyncE.
- SyncE on 1G interfaces only supports 1000BASE-SX transceivers, 1000BASE-LX transceivers, and ADVA 5401 GrandMaster transceivers.
- When you configure SyncE on a switch with PTP enabled, configure ITU-T noise transfer.
- To use SyncE on the SN5400 switch running Cumulus Linux 5.11 or later, you must upgrade SyncE firmware. See Upgrade SyncE Firmware on the SN5400 Switch below.
Upgrade SyncE Firmware on the NVIDIA SN5400 Switch
The NVIDIA SN5400 switch running Cumulus Linux 5.11 and later requires a firmware upgrade to use SyncE.
To upgrade the SyncE firmware on the SN5400 switch:
-
On the NVIDIA Enterprise support portal, click the More Files tab to download all the SyncE firmware files.
-
Upload the SyncE firmware files to the switch.
-
Upgrade the firmware with the
sudo flint
command for each file; for example:cumulus@switch:~$ sudo flint -d /dev/mst/mt53120_pciconf0 -i MC000030_HIPPO_ALBATROSS_CLKBRD1_CLK_FW_UPGRADE_REV0100.bin burn Current FW version on flash: 0.0 New FW version: 1.0 -I- Downloading FW ... FSMST_INITIALIZE - OK Writing COMPID_CLOCK_SYNC_EEPROM component - OK FSMST_LOCKED - OK FSMST_DOWNSTREAM_DEVICE_TRANSFER - OK -I- Component FW burn finished successfully. -I- To load new FW run reboot machine.
cumulus@switch:~$ sudo flint -d /dev/mst/mt53120_pciconf0 -i MC000031_HIPPO_ALBATROSS_CLKBRD2_CLK_FW_UPGRADE_REV0100.bin burn Current FW version on flash: 0.0 New FW version: 1.0 -I- Downloading FW ... FSMST_INITIALIZE - OK Writing COMPID_CLOCK_SYNC_EEPROM component - OK FSMST_LOCKED - OK FSMST_DOWNSTREAM_DEVICE_TRANSFER - OK -I- Component FW burn finished successfully. -I- To load new FW run reboot machine.
-
Completely reset the system by removing power for at least 30 seconds.
Basic Configuration
Basic SyncE configuration requires you:
- Enable SyncE on the switch.
- Configure SyncE on at least one interface so that the interface is a timing source that passes to the selection algorithm.
- Set the SyncE bundle ID to prevent loops if more than one link comes from the same clock source. You can set a value between 1 and 256.
The basic configuration shown below uses the default SyncE settings:
- The frequency source priority on the interface is set to 100.
- The amount of time SyncE waits after the interface comes up before using the interface for synchronization is set to 5 minutes.
cumulus@switch:~$ nv set system synce state enabled
cumulus@switch:~$ nv set interface swp2 synce state enabled
cumulus@switch:~$ nv set interface swp2 synce bundle-id 10
cumulus@switch:~$ nv config apply
Edit the /etc/synced/synced.conf
file to configure the interface, then enable and start the SyncE service. Adding an interface section in the /etc/synced/synced.conf
file enables SyncE on that interface.
The following example enables SyncE on swp2.
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
# NVUE SyncE state is enabled
[global]
twtr_seconds=300
priority=1
[swp2]
bundle=10
cumulus@switch:~$ sudo systemctl enable synced.service
cumulus@switch:~$ sudo systemctl start synced.service
Optional Global Configuration
Wait to Restore Time
The wait to restore time is the number of seconds SyncE waits for each port to be up before opening the Ethernet Synchronization Message Channel (ESMC) for messages. You can set a value between 0 and 720 (12) minutes. The default value is 300 seconds (5 minutes).
The following command example sets the wait to restore time to 180 seconds (3 minutes):
cumulus@switch:~$ nv set system synce wait-to-restore-time 180
cumulus@switch:~$ nv config apply
Edit the /etc/synced/synced.conf
file to change the twtr_seconds setting
, then restart the SyncE service.
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
[global]
twtr_seconds=180
cumulus@switch:~$ sudo systemctl restart synced.service
Priority
You can set the priority for the clock source. The lowest priority is 1 and the highest priority is 256. If two clock sources have the same priority, the switch uses the lowest clock source.
The following example command sets the priority to 256:
cumulus@switch:~$ nv set system synce provider-default-priority 256
cumulus@switch:~$ nv config apply
Edit the /etc/synced/synced.conf
file to change the priority
setting, then restart the SyncE service.
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
[global]
twtr_seconds=180
priority=256
cumulus@switch:~$ sudo systemctl restart synced.service
Minimum Acceptable Quality Level
You can prevent SyncE from tracking a source with a quality level lower than a specific value. The quality level can be: eec1
, eeec
, ssu-b
, ssu-a
, prc
, eprc
, prtc
, or eprtc
, where eec1
is the lowest quality level and eprtc
is the highest quality level.
Run the nv set system synce min-acceptable-ql <quality-level>
command. The following example prevents SyncE from tracking a source with a quality level lower than ssu-b
:
cumulus@switch:~$ nv set system synce min-acceptable-ql ssu-b
cumulus@switch:~$ nv config apply
Edit the /etc/synced/synced.conf
file to add the min_ql
parameter, then restart the SyncE service. The following example prevents SyncE from tracking a source with a quality level lower than ssu-b
:
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
min_ql=ssu-b
cumulus@switch:~$ sudo systemctl restart synced.service
Logging
You can set the logging level that the SyncE service uses:
critical
level logs critical errors and notices.debug
level logs fine-grained informational events that are most useful to debug an application.error
level logs errors.info
level logs informational messages.notice
level logs notices.
The following example command sets the logging level to debug
.
cumulus@switch:~$ nv set system synce log-level debug
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the log-level
setting, then reload the SyncE service.
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
[global]
twtr_seconds=180
priority=256
loglevel=debug
cumulus@switch:~$ sudo systemctl reload synced.service
Optional Interface Configuration
Frequency Source Priority
The clock selection algorithm uses the frequency source priority on an interface to choose between two sources that have the same QL. You can specify a value between 1 (the highest priority) and 256 (the lowest priority). The default value is 1.
The following command example sets the priority on swp2 to 10, on swp2 to 20, and on swp3 to 10:
cumulus@switch:~$ nv set interface swp1 synce provider-priority 10
cumulus@switch:~$ nv set interface swp2 synce provider-priority 20
cumulus@switch:~$ nv set interface swp3 synce provider-priority 10
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the priority
setting for the interface, then restart the SyncE service.
cumulus@switch:~$ sudo nano /etc/synced/synced.conf
...
[global]
twtr_seconds=180
priority=256
log-level=debug
[swp1]
priority=10
[swp2]
priority=20
[swp3]
priority=10
cumulus@switch:~$ sudo systemctl restart synced.service
Troubleshooting
Show SyncE Configuration and Counters
To show global SyncE configuration, run the NVUE nv show system synce
command or the Linux syncectl show status
command.
To show SyncE configuration for a specific interface, run the NVUE nv show interface <interface-id> synce
command or the Linux syncectl show interface status <interface-id>
command.
cumulus@switch:~$ nv show system synce
operational applied
------------------------- ----------------------------------------------------------------- -------
state enabled enabled
wait-to-restore-time 10 10
log-level notice
provider-default-priority 1 1
min-acceptable-ql eec1
local-clock-identity 0x9c0591fffe49be00
reference-clock-identity 0x001201fffe000001
is-extended-tlv Extended TLV
network-type 1
local-clock-quality eeec
oper-status self-track
holdover-acquired yes
tracking-port swp1
cumulus@switch:~$ nv show interface swp5 synce
operational applied
------------------ ----------- -------
state enabled enabled
provider-priority 1
esmc
transmit enabled enabled
receive enabled enabled
admin-status tracking
operational-status self-track
quality-level-in eprc
quality-level-out dnu
frequency-diff-ppb -26
holdover-acquired no
cascaded-eec-in 0
cascaded-eec-out 0
cascaded-e-eec-in 1
cascaded-e-eec-out 2
In the command outputs above, the oper-status
and operational-status
fields can be one of the following.
Operational Status | Description |
---|---|
free-running |
The PLL runs only on its local oscillator. You see this when no synce source is selected. |
holdover |
If the selected reference is intentionally removed (port down, unselected reference), the PLL uses the last learned frequency profile. |
self-track |
The PLL is locked to the currently selected reference input. |
other-track |
The PLL is synchronized temporarily to an alternate valid reference port (not the primary one). This happens when the selected reference becomes unusable and the PLL switches automatically to another available source to maintain synchronization. |
holdover-due-to-failure |
The PLL loses reference unexpectedly (a loss of signal or a frequency slip). Because a valid history exists, the PLL holds its last frequency. |
free-running-due-to-failure |
The PLL starts out locked (tracking a reference) but the reference disappears before the PLL can capture the history for holdover. |
The holdover-acquired
field indicates that PLL has successfully learned the last good reference and is now capable of entering holdover if that reference disappears. It does not mean the PLL is currently in holdover, only that it has the history ready.
The tracking-port
field shows the port to which the PLL is currently locked.
To show SyncE statistics for a specific interface, run the NVUE nv show interface <interface-id> counters synce
command or the Linux syncectl show interface counters <interface
command:
cumulus@switch:~$ nv show interface swp2 counters synce
Packet Type Received Transmitted
--------------------- ------------ ------------
ESMC 700 708
ESMC Error 0 0
ESMC DNU 549 0
ESMC EEC1 1 558
ESMC E-EEC 0 0
ESMC SSU B 0 0
ESMC SSU A 0 0
ESMC PRC 150 150
ESMC E-PRC 0 0
ESMC PRTC 0 0
ESMC E-PRTC 0 0
ESMC Unknown 0 0
Clear SyncE Interface Counters
To clear counters for a specific SyncE interface, run the NVUE nv action clear interface <interface-id> counters synce
command or the Linux syncectl clear interface counters <interface-id>
command.
cumulus@switch:~$ nv action clear interface swp1 counters synce
swp1 counters cleared
Action succeeded
To clear counters for all SyncE interfaces, run the syncectl clear counters
command.
To see all the syncectl