Monitoring System Statistics and Network Traffic with sFlow

sFlow is a monitoring protocol that samples network packets, application operations, and system counters. sFlow collects both interface counters and sampled 5-tuple packet information so that you can monitor your network traffic as well as your switch state and performance metrics. To collect and analyze this data, you need an outside server; an sFlow collector.

If you intend to run this service within a VRF, including the management VRF, follow these steps to configure the service.

Configure sFlow

To configure sFlow:

  • Provide the sFlow collectors. You must configure at least one collector if you enable sFlow.
  • Set the sFlow sampling rate.
  • Set the polling interval.
  • Provide the IP address and interface of the sFlow agent.
  • Configure the sFlow policer rate and policer burst.
  • Enable sFlow

Cumulus Linux provides different sampling rate configurations. The value represents the sampling ratio; for example, if you specify a value of 400, SFlow samples one in every 400 packets.

Sampling Rate Default Value Description
speed-100m 100 The sampling rate on a 100Mbps port.
speed-1g 1000 The sampling rate on a 1Gbps port.
speed-10g 10000 The sampling rate on a 10Gbps port.
speed-40g 40000 The sampling rate on a 40Gbps port.
speed-50g 50000 The sampling rate on a 50Gbps port.
speed-100g 100000 The sampling rate on a 100Gbps port.
speed-200g 200000 The sampling rate on a 200Gbps port.
speed-400g 400000 The sampling rate on a 400Gbps port.
speed-800g 800000 The sampling rate on a 800Gbps port.

Some collectors require each source to transmit on a different port, others listen on only one port. Refer to the documentation for your collector for more information.

Configure Designated Collectors

Specify the IP address, UDP port number, and interface for the designated collectors. The port number and interface are optional; If you do not specify a port number, Cumulus Linux uses the default port 6343.

The following example configures sFlow to send data to collector 192.0.2.100 on port 6343 and collector 192.0.2.200 on eth0:

cumulus@switch:~$ nv set system sflow collector 192.0.2.100 port 6344
cumulus@switch:~$ nv set system sflow collector 192.0.2.200 interface eth0
cumulus@switch:~$ nv config apply

Configure the sFlow sampling rate in number of packets if you do not want to use the default rate, and the polling interval in seconds.

The following example polls the counters every 20 seconds and samples one in every 40000 packets for 40G interfaces:

cumulus@switch:~$ nv set system sflow sampling-rate speed-40g 40000
cumulus@switch:~$ nv set system sflow poll-interval 20
cumulus@switch:~$ nv config apply

Edit the /etc/hsflowd.conf file to set up the collectors, sampling rates, and polling interval in seconds, then restart the hsflowd service with the sudo systemctl start hsflowd command.

The following example polls the counters every 20 seconds, samples 1 of every 40000 packets for 40G interfaces, and sends this information to a collector at 192.0.2.100 on port 6343 and to another collector at 192.0.2.200 on interface eth0.

cumulus@switch:~$ sudo nano /etc/hsflowd.conf
sflow {
# ====== Sampling/Polling/Collectors ======
  # EITHER: automatic (DNS SRV+TXT from _sflow._udp):
  #   DNS-SD { }
  # OR: manual:
  #   Counter Polling:
        polling = 20
  #   default sampling N:
  #     sampling = 400
  #   sampling N on interfaces with ifSpeed:
        sampling.100M = 100
        sampling.1G = 1000
        sampling.10G = 10000
        sampling.40G = 40000
  #   sampling N for apache, nginx:
  #     sampling.http = 50
  #     sampling N for application (requires json):
  #     sampling.app.myapp = 100
  #   collectors:
  collector { ip=192.0.2.100 udpport=6344 }
  collector { ip=192.0.2.200 interface=eth0 }
}
cumulus@switch:~$ sudo systemctl start hsflowd

Configure the SFlow Agent

Provide the IP address or prefix, or the interface for the sFlow agent.

The following example configures the sFlow agent prefix to 10.0.0.0/8:

cumulus@switch:~$ nv set system sflow agent ip 10.0.0.0/8
cumulus@switch:~$ nv config apply

The following example configures the sFlow agent interface to eth0:

cumulus@switch:~$ nv set system sflow agent interface eth0
cumulus@switch:~$ nv config apply

To provide the IP address or prefix for the sFlow agent, edit the /etc/hsflowd.conf file to set the agent.CIDR parameter, then restart the hsflowd service with the sudo systemctl start hsflowd command.

cumulus@switch:~$ sudo nano /etc/hsflowd.conf
...
sflow { 
  agent.CIDR = 10.0.0.0/8 
} 
cumulus@switch:~$ sudo systemctl start hsflowd

To provide an interface for the sFlow agent, edit the /etc/hsflowd.conf file to set the agent parameter, then restart the hsflowd service with the sudo systemctl start hsflowd command.:

cumulus@switch:~$ sudo nano /etc/hsflowd.conf
...
sflow { 
  agent = eth0 
} 
cumulus@switch:~$ sudo systemctl start hsflowd

Configure sFlow Policer Rate and Burst Size

You can limit the number of sFlow samples per second and the sample burst size per second that the switch sends.

The default number of sFlow samples and default sample size is 16384. You can specify a value between 0 and 16384.

The following example sets the number of sFlow samples to 800 and the sample size to 900:

cumulus@switch:~$ nv set system sflow policer rate 8000
cumulus@switch:~$ nv set system sflow policer burst 9000
cumulus@switch:~$ nv config apply

Edit the /etc/cumulus/datapath/traffic.conf file to change the sflow.rate and sflow.burst parameters, then reload switchd with the sudo systemctl reload switchd.service command.

cumulus@switch:~$ sudo nano /etc/cumulus/datapath/traffic.conf
# Set sflow/sample ingress cpu packet rate and burst in packets/sec 
# Values: {0..16384} 
sflow.rate = 8000
sflow.burst = 9000 
cumulus@switch:~$ sudo systemctl reload switchd.service 

Enable sFlow

To enable sFlow:

cumulus@switch:~$ nv set system sflow state enabled 
cumulus@switch:~$ nv config apply

To disable sFlow, run the nv set system sflow state disabled command.

By default, the hsflowd service is disabled and does not start automatically when the switch boots up.

To enable and start the hsflowd service:

cumulus@switch:~$ sudo systemctl enable hsflowd
cumulus@switch:~$ sudo systemctl start hsflowd

To disable the hsflowd service:

cumulus@switch:~$ sudo systemctl stop hsflowd
cumulus@switch:~$ sudo systemctl disable hsflowd

Interface Configuration

By default, sFlow is enabled on interfaces that are operationally UP. To disable sFlow on an interface:

cumulus@switch:~$ nv set interface swp1 sflow state disabled 
cumulus@switch:~$ nv config apply

To enable sFlow on an interface, run the nv set interface <interface> sflow state enabled command.

By default, sFlow is enabled on interfaces that are operationally UP. To disable sFlow on a specific interface, edit the /etc/cumulus/switchd.conf file and set the interface.<interface>.sflow.enable parameter to FALSE:

cumulus@switch:~$ sudo nano /etc/cumulus/switchd.conf
interface.swp1.sflow.enable = FALSE 

To enable sFlow on an interface, set the interface.<interface>.sflow.enable parameter to TRUE.

To configure the sFlow sample rate on an interface.

cumulus@switch:~$ nv set interface swp1 sflow sample-rate 100000
cumulus@switch:~$ nv config apply

Edit the /etc/cumulus/switchd.conf file and set the interface.<interface-id>.sflow.sample_rate.ingress parameter:

cumulus@switch:~$ sudo nano /etc/cumulus/switchd.conf
interface.swp1.sflow.sample_rate.ingress = 100000 

Monitor Dropped Packets

You can configure sFlow to monitor dropped packets in hardware.

cumulus@switch:~$ nv set system sflow dropmon hw 
cumulus@switch:~$ nv config apply

Edit the /etc/hsflowd.conf file to change start to on in the dropmon { group=1 start=off limit=1000 } line.

cumulus@switch:~$ sudo nano /etc/hsflowd.conf
dropmon { group=1 start=on limit=1000 }

Restart the hsflowd service with the sudo systemctl start hsflowd command.

Configure sFlow Visualization Tools

For information on configuring various sFlow visualization tools, read this knowledge base article.

Show sFlow Configuration

To show all sFlow configuration on the switch:

cumulus@switch:~$ nv show system sflow
                operational  applied    
-------------  -----------  -----------
poll-interval               20         
state                       enabled    
[collector]                 192.0.2.100
[collector]                 192.0.2.200
sampling-rate                          
  default                   400        
  speed-100m                100        
  speed-1g                  1000       
  speed-10g                 10000      
  speed-25g                 25000      
  speed-40g                 40000      
  speed-50g                 50000      
  speed-100g                100000     
  speed-200g                200000     
  speed-400g                400000     
  speed-800g                800000     
agent                                  
  ip                        10.0.0.0/8 
  interface                 eth0       
policer                                
  rate                      8000       
  burst                     9000       
[dropmon]                   sw

To show sFlow collector configuration:

cumulus@switch:~$ nv show system sflow collector
Ip                    Port 
--------------------------------- 
192.0.2.100           6343 
192.0.2.200           6344

To show the sFlow sampling rate configuration:

cumulus@switch:~$ nv show system sflow sampling-rate
            applied
----------  -------
default     400    
speed-100m  100    
speed-1g    1000   
speed-10g   10000  
speed-25g   25000  
speed-40g   40000  
speed-50g   50000  
speed-100g  100000 
speed-200g  200000 
speed-400g  400000 
speed-800g  800000 

To show sFlow agent configuration:

cumulus@switch:~$ nv show system sflow agent
           operational  applied   
---------  -----------  ----------
ip                      10.0.0.0/8
interface               eth0

To show the number of samples per second and the sample burst size per second that the switch sends out:

cumulus@switch:~$ nv show system sflow policer
---------------------- 
       applied
-----  -------
rate   8000   
burst  9000

To show sFlow configuration on a specific interface:

cumulus@switch:~$ nv show interface swp1 sflow
---------------------- 
             operational  applied
-----------  -----------  -------
sample-rate  0            100000 
state        disabled     enabled

Considerations

Cumulus Linux does not support sFlow egress sampling.