RDMA over Converged Ethernet - RoCE
RDMA over Converged Ethernet (RoCE) provides the ability to write to compute or storage elements using remote direct memory access (RDMA) over an Ethernet network instead of using host CPUs. RoCE relies on congestion control and lossless Ethernet to operate. Cumulus Linux supports features that can enable lossless Ethernet for RoCE environments. Note that while Cumulus Linux can support RoCE environments, the hosts send and receive the RoCE packets.
RoCE helps you obtain a converged network, where all services run over the Ethernet infrastructure, including Infiniband apps.
There are two versions of RoCE, which run at separate layers of the stack:
- RoCEv1, which runs at the link layer and cannot be run over a routed network. Therefore, it requires the link layer priority flow control (PFC) to be enabled.
- RoCEv2, which runs over layer 3. Since it’s a routed solution, consider using explicit congestion notification (ECN) with RoCEv2 since ECN bits are communicated end-to-end across a routed network.
Enable RDMA over Converged Ethernet with PFC
RoCEv1 uses the Infiniband (IB) Protocol over converged Ethernet. The IB global route header rides directly on top of the Ethernet header. The lossless Ethernet layer handles congestion hop by hop.
To learn the Cumulus Linux settings you need to configure to support RoCEv1, see the example configuration in the PFC section of the Buffer and Queue Management chapter.
On switches with Spectrum ASICs, you can alternately use NCLU to configure RoCE with PFC:
cumulus@switch:~$ net add interface swp1 storage-optimized pfc
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit
These commands create the following configuration in the /etc/cumulus/datapath/traffic.conf
and /usr/lib/python2.7/dist-packages/cumulus/__chip_config/mlx/datapath.conf
files.
The most notable changes involve configuring both PFC and ECN on cos 3 in
/etc/cumulus/datapath/traffic.conf
file. They also add a flow control buffer pool for
lossless traffic and change the buffer limits in the
/usr/lib/python2.7/dist-packages/cumulus/__chip_config/mlx/datapath.conf
file.
cumulus@switch:~$ sudo cat /etc/cumulus/datapath/traffic.conf
...
# packet header field used to determine the packet priority level
# fields include {802.1p, dscp}
traffic.packet_priority_source_set = [dscp]
# dscp values = {0..63}
traffic.cos_0.priority_source.dscp = [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63]
traffic.cos_1.priority_source.dscp = []
traffic.cos_2.priority_source.dscp = [48]
traffic.cos_3.priority_source.dscp = [26]
traffic.cos_4.priority_source.dscp = []
traffic.cos_5.priority_source.dscp = []
traffic.cos_6.priority_source.dscp = []
traffic.cos_7.priority_source.dscp = []
...
# internal cos values assigned to each priority group
# each cos value should be assigned exactly once
# internal cos values {0..7}
priority_group.control.cos_list = [2]
priority_group.service.cos_list = [3]
priority_group.bulk.cos_list = [0,1,4,5,6,7]
...
# priority flow control
pfc.port_group_list = [ROCE_PFC]
pfc.pfc_port_group.cos_list = [3]
pfc.pfc_port_group.port_set = swp1
pfc.pfc_port_group.port_buffer_bytes = 70000
pfc.pfc_port_group.xoff_size = 18000
pfc.pfc_port_group.xon_delta = 0
pfc.pfc_port_group.tx_enable = true
pfc.pfc_port_group.rx_enable = true
...
# Explicit Congestion Notification
# to configure ECN and RED on a group of ports:
# -- add or replace port group names in the port group list
# -- assign cos value(s) to the cos list
# -- for each port group in the list
# -- populate the port set, e.g.
# swp1-swp4,swp8,swp50s0-swp50s3
# -- to enable RED requires the latest traffic.conf
ecn_red.port_group_list = [ROCE_ECN]
ecn_red.ecn_red_port_group.cos_list = [3]
ecn_red.ecn_red_port_group.port_set = swp1
ecn_red.ecn_red_port_group.ecn_enable = true
ecn_red.ecn_red_port_group.red_enable = false
ecn_red.ecn_red_port_group.min_threshold_bytes = 153600
ecn_red.ecn_red_port_group.max_threshold_bytes = 1536000
ecn_red.ecn_red_port_group.probability = 100
# scheduling algorithm: algorithm values = {dwrr}
scheduling.algorithm = dwrr
# traffic group scheduling weight
# weight values = {0..127}
# '0' indicates strict priority
priority_group.control.weight = 0
priority_group.service.weight = 16
priority_group.bulk.weight = 16
...
cumulus@mlnx:~$ sudo cat /usr/lib/python2.7/dist-packages/cumulus/__chip_config/mlx/datapath.conf
...
# ingress service pool buffer allocation: percent of total buffer
# If a service pool has no priority groups, the buffer is added
# to the shared buffer space.
ingress_service_pool.0.percent = 50.0 # all priority groups
...
# Service pool buffer allocation: percent of total
# buffer size.
egress_service_pool.0.percent = 50.0 # all priority groups, UC and MC
...
# Resilient hash timers: in milliseconds
# resilient_hash_active_timer = 120000
# resilient_hash_max_unbalanced_timer = 4294967295
priority_group.control.id = 0
priority_group.service.id = 0
priority_group.bulk.id = 0
priority_group.control.service_pool = 0
priority_group.service.service_pool = 0
priority_group.bulk.service_pool = 0
ingress_service_pool.0.mode = 1
egress_service_pool.0.mode = 1
flow_control.service_pool = 1
ingress_service_pool.1.percent = 50.0
ingress_service_pool.1.mode = 1
egress_service_pool.1.percent = 100.0
egress_service_pool.1.mode = 1
priority_group.control.ingress_buffer.dynamic_quota = 11
priority_group.service.ingress_buffer.dynamic_quota = 11
priority_group.bulk.ingress_buffer.dynamic_quota = 11
flow_control.ingress_buffer.dynamic_quota = 9
priority_group.bulk.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.service.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.control.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.bulk.egress_buffer.mc.sp_dynamic_quota = 9
priority_group.service.egress_buffer.mc.sp_dynamic_quota = 9
priority_group.control.egress_buffer.mc.sp_dynamic_quota = 9
While link pause is another way to provide lossless ethernet, PFC is the preferred method. PFC allows more granular control by pausing the traffic flow for a given CoS group, rather than the entire link.
Enable RDMA over Converged Ethernet with ECN
RoCEv2 requires flow control for lossless Ethernet. RoCEv2 uses the Infiniband (IB) Transport Protocol over UDP. The IB transport protocol includes an end-to-end reliable delivery mechanism, and has its own sender notification mechanism.
RoCEv2 congestion management uses RFC 3168 to signal congestion experienced to the receiver. The receiver generates an RoCEv2 congestion notification packet directed to the source of the packet.
To learn the Cumulus Linux settings you need to configure to support RoCEv2, see the example configuration in the ECN section of the Buffer and Queue Management chapter.
On switches with Spectrum ASICs, you can alternately use NCLU to configure RoCE with ECN:
cumulus@switch:~$ net add interface swp1 storage-optimized
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit
These commands create the following configuration in the
/etc/cumulus/datapath/traffic.conf
file:
cumulus@switch:~$ sudo cat /etc/cumulus/datapath/traffic.conf
...
# packet header field used to determine the packet priority level
# fields include {802.1p, dscp}
traffic.packet_priority_source_set = [dscp]
...
# dscp values = {0..63}
traffic.cos_0.priority_source.dscp = [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63]
traffic.cos_1.priority_source.dscp = []
traffic.cos_2.priority_source.dscp = [48]
traffic.cos_3.priority_source.dscp = [26]
traffic.cos_4.priority_source.dscp = []
traffic.cos_5.priority_source.dscp = []
traffic.cos_6.priority_source.dscp = []
traffic.cos_7.priority_source.dscp = []
...
The storage-optimized
command changes the buffer limits in the
/usr/lib/python2.7/dist-packages/cumulus/__chip_config/mlx/datapath.conf
file.
It also enables drop behaviors and Random Early Detection (RED). RED identifies packets that have been added to a long egress queue. The ECN action marks the packet and forwards it, requiring the packet to be ECT-capable. However, the drop action drops the packet, requiring the packet to not be ECT-capable.
cumulus@switch:~$ sudo cat /usr/lib/python2.7/dist-packages/cumulus/__chip_config/mlx/datapath.conf
...
# Resilient hash timers: in milliseconds
# resilient_hash_active_timer = 120000
# resilient_hash_max_unbalanced_timer = 4294967295
priority_group.control.id = 0
priority_group.service.id = 0
priority_group.bulk.id = 0
priority_group.control.service_pool = 0
priority_group.service.service_pool = 0
priority_group.bulk.service_pool = 0
ingress_service_pool.0.mode = 1
egress_service_pool.0.mode = 1
priority_group.control.ingress_buffer.dynamic_quota = 11
priority_group.service.ingress_buffer.dynamic_quota = 11
priority_group.bulk.ingress_buffer.dynamic_quota = 11
priority_group.bulk.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.service.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.control.egress_buffer.uc.sp_dynamic_quota = 11
priority_group.bulk.egress_buffer.mc.sp_dynamic_quota = 9
priority_group.service.egress_buffer.mc.sp_dynamic_quota = 9
priority_group.control.egress_buffer.mc.sp_dynamic_quota = 9
...
# internal cos values assigned to each priority group
# each cos value should be assigned exactly once
# internal cos values {0..7}
priority_group.control.cos_list = [2]
priority_group.service.cos_list = [3]
priority_group.bulk.cos_list = [0,1,4,5,6,7]
...
# Explicit Congestion Notification
# to configure ECN and RED on a group of ports:
# -- add or replace port group names in the port group list
# -- assign cos value(s) to the cos list
# -- for each port group in the list
# -- populate the port set, e.g.
# swp1-swp4,swp8,swp50s0-swp50s3
# -- to enable RED requires the latest traffic.conf
ecn_red.port_group_list = [ROCE_ECN]
ecn_red.ecn_red_port_group.cos_list = [3]
ecn_red.ecn_red_port_group.port_set = swp1
ecn_red.ecn_red_port_group.ecn_enable = true
ecn_red.ecn_red_port_group.red_enable = false
ecn_red.ecn_red_port_group.min_threshold_bytes = 153600
ecn_red.ecn_red_port_group.max_threshold_bytes = 1536000
ecn_red.ecn_red_port_group.probability = 100
...
# traffic group scheduling weight
# weight values = {0..127}
# '0' indicates strict priority
priority_group.control.weight = 0
priority_group.service.weight = 16
...
Related Information
- RoCE introduction - roceinitiative.org
- RoCEv2 congestion management - community.mellanox.com
- Configuring RoCE over a DSCP-based lossless network with a Mellanox Spectrum switch