Monitoring System Statistics and Network Traffic with sFlow
sFlow is a monitoring protocol that samples network packets, application operations, and system counters. sFlow collects both interface counters and sampled 5-tuple packet information, enabling you to monitor your network traffic as well as your switch state and performance metrics. An outside server, known as an sFlow collector, is required to collect and analyze this data.
hsflowd
is the service that samples and sends sFlow data to configured
collectors. By default, hsflowd
is disabled and does not start
automatically when the switch boots up.
- sFlow is not supported on Broadcom switches with the Hurricane2 ASIC.
- The
hsflowd
service does not sample interfaces that are up but not configured. - If you intend to run this service within a VRF, including the management VRF, follow these steps for configuring the service.
Configure sFlow
To configure hsflowd
to send to the designated collectors, either:
- Use DNS service discovery (DNS-SD)
- Manually configure the
/etc/hsflowd.conf
file
Configure sFlow via DNS-SD
You can configure your DNS zone to advertise the collectors and polling information to all interested clients.
Add the following content to the zone file on your DNS server:
_sflow._udp SRV 0 0 6343 collector1
_sflow._udp SRV 0 0 6344 collector2
_sflow._udp TXT (
"txtvers=1"
"sampling.100M=100"
"sampling.1G=1000"
"sampling.10G=10000"
"sampling.40G=40000"
"sampling.100G=100000"
"polling=20"
)
The above snippet instructs hsflowd
to send sFlow data to collector1
on port 6343 and to collector2 on port 6344. hsflowd
will poll
counters every 20 seconds and sample 1 out of every 2048 packets.
The maximum samples per second delivered from the hardware is limited to
16K. You can configure the number of samples per second in the
/etc/cumulus/datapath/traffic.conf
file, as shown below:
# Set sflow/sample ingress cpu packet rate and burst in packets/sec
# Values: {0..16384}
#sflow.rate = 16384
#sflow.burst = 16384
Start the sFlow daemon:
cumulus@switch:~$ sudo systemctl start hsflowd.service
No additional configuration is required in /etc/hsflowd.conf
.
Manually Configure /etc/hsflowd.conf
You can set up the collectors and variables on each switch.
Edit the /etc/hsflowd.conf
file to set up your collectors and sampling
rates in /etc/hsflowd.conf
. For example:
sflow {
# ====== Sampling/Polling/Collectors ======
# EITHER: automatic (DNS SRV+TXT from _sflow._udp):
# DNS-SD { }
# OR: manual:
# Counter Polling:
polling = 20
# default sampling N:
# sampling = 400
# sampling N on interfaces with ifSpeed:
sampling.100M = 100
sampling.1G = 1000
sampling.10G = 10000
sampling.40G = 40000
# sampling N for apache, nginx:
# sampling.http = 50
# sampling N for application (requires json):
# sampling.app.myapp = 100
# collectors:
collector { ip=192.0.2.100 udpport=6343 }
collector { ip=192.0.2.200 udpport=6344 }
}
This configuration polls the counters every 20 seconds, samples 1 of every 40000 packets for 40G interfaces, and sends this information to a collector at 192.0.2.100 on port 6343 and to another collector at 192.0.2.200 on port 6344.
Some collectors require each source to transmit on a different port, others listen on only one port. Refer to the documentation for your collector for more information.
To configure the IP address for the sFlow agent, configure one of the following the /etc/hsflowd.conf
file (following the recommendations in the sFlow documentation):
- The agent CIDR. For example,
agent.cidr = 10.0.0.0/8
. The IP address should fall within this range. - The agent interface. For example, if the agent is using eth0, select the IP address associated with this interface.
You can check to see which agent IP was selected using:
cumulus@switch:~$ grep agentIP /etc/hsflowd.auto
Configure sFlow Visualization Tools
For information on configuring various sFlow visualization tools, read this knowledge base article.
Caveats and Errata
The EdgeCore AS4610 switch occasionally sends malformed packets and does not send any flow samples; it sends only counters. This is a known limitation on this Helix4 platform.
Considerations
Mellanox switches do not support sFlow egress sampling.