SyncE
SyncE is a standard for transmitting clock signals over the Ethernet physical layer to synchronize clocks across the network by propagating frequency using the transmission rate of symbols in the network. A dedicated Ethernet channel, (ESMC), manages this synchronization.
The Cumulus Linux switch includes a SyncE controller and a SyncE daemon.
- The SyncE controller reads performance counters to calculate the differences between TX and RX ethernet symbols on the physical layer to fine tune the clock frequency.
- The SyncE daemon (
syncd
) manages:- Transmitting and receiving SSMs on all SyncE enabled ports using the Ethernet Synchronization Messaging Channel (ESMC).
- The synchronization hierarchy and runs the master selection algorithm to choose the best reference clock from the QL in the SSM.
- Using to the next best clock when the master clock fails. The selection algorithm only selects the best source, which is the Primary Clock source.
- The switchover time if the algorithm also selects a secondary reference clock in case of primary failure.
Cumulus Linux supports SyncE on the NVIDIA SN3700-S switch only as an early access feature.
Basic Configuration
Basic SyncE configuration requires you:
- Enable SyncE on the switch.
- Configure SyncE on at least one interface or bond so that the interface is a timing source that passes to the selection algorithm.
The basic configuration shown below uses the default settings:
- The QL for the switch is set to
option 1
, which includes PRC, SSU-A, SSU-B, SEC and DNU. - The frequency source priority on the interface is set to 100.
- The amount of time SyncE waits after the interface comes up before using it for synchronization is set to 5 minutes.
cumulus@switch:~$ nv set synce enable on
cumulus@switch:~$ nv set interface swp2 synce enable on
cumulus@switch:~$ nv config apply
Optional Global Configuration
QL for the Switch
You can specify the ITU-T QL for the switch. You can specify one of the following values. The default is option 1
.
option 1
includes PRC, SSU-A, SSU-B, SEC and DNU.option 2
includes PRS, STU, ST2, ST3, SMC, ST4, RES and DUS.option 3
includes PRS, STU, ST2, ST3, TNC, ST3E, SMC, ST4, PROV and DUS.
The following command example sets the QL for the switch to option 2
:
cumulus@switch:~$ nv set synce network-type option 2
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the QL setting, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
Logging
By default, SyncE logging is off on the switch. You can enable logging to write a log message:
- Every time there is a change to the selected source in addition to errors
- Only when there are no available frequency sources or when the only available frequency source is the internal oscillator
The following command example sets logging to write a log message every time there is a change to the selected source in addition to errors:
cumulus@switch:~$ nv set synce changes
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the logging setting, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
The following command example sets logging to write a log message only when there are no available frequency sources or when the only available frequency source is the internal oscillator:
cumulus@switch:~$ nv set synce errors
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the logging setting, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
Optional Interface Configuration
Frequency Source Priority
The clock selection algorithm uses the frequency source priority on an interface to choose between two sources that have the same QL. You can specify a value between 1 (the highest priority) and 254 (the lowest priority). The default value is 100.
The following command example sets the priority on swp2 to 254:
cumulus@switch:~$ nv set interface swp2 synce priority 254
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the priority setting, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
Wait to Restore Time
The wait to restore time is the amount of time SyncE waits after the interface comes up before using it for synchronization. You can set a value betwen 0 and 12 minutes. The default value is 5 minutes.
The following command example sets the wait to restore time to 3 minutes:
cumulus@switch:~$ nv set interface swp2 synce wait-to-restore 3
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to change the wait to restore time setting, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
Disable Synchronization Status Messages
You can disable SSMs on an interface to prevent sending ESMC packets and ignore any received ESMC packets.
The following command example disables SSMs on swp2:
cumulus@switch:~$ nv set interface swp2 synce ssm disable
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to disable SSMs, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
QL to Transmit in Status Messages
To override the QL (option 1
, option 2 generation 1
, or option 2 generation 2
) transmitted in SSM messages, you can set the following options:
exact <ql>
specifies the exact QL regardless of the value received.highest <ql>
specifies an upper limit on the QL. If the selected source has a higher QL than the QL specified here, the switch transmits this QL instead.lowest <ql>
specifies a lower limit on the QL. If the selected source has a lower QL than the QL specified here, the switch transmits DNU instead.
The following command example specifies an upper limit of option 1
:
cumulus@switch:~$ nv set interface swp2 synce highest option 1
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to specify an upper limit of option 1
, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
The QL must match the globally configured QL with the network-type
command.
QL to Receive in Status Messages
To override the QL (option 1
, option 2 generation 1
, or option 2 generation 2
) received in SSM messages before using it in the selection algorithm, you can set one of the following options:
exact <quality-level>
specifies the exact QL regardless of the value received unless the received value is DNU.highest <quality-level>
specifies an upper limit on the received QL. If the received value is higher than this specified QL, the switch transmits this QL instead.lowest <quality-level>
specifies a lower limit on the received QL. If the received value is lower than this specified QL, the switch transmits DNU instead.
The following command example specifies a lower limit of option 2 generation 1
:
cumulus@switch:~$ nv set interface swp2 synce lowest option 2 generation 1
cumulus@switch:~$ nv config apply
Edit the /etc/synced.conf
file to specify a lower limit of option 2 generation 1
, then restart the syncd
service.
EXAMPLE FILE HERE
cumulus@switch:~$ sudo systemctl restart syncd
The QL to receive must match the globally configured QL set with the network-type
command.
Troubleshooting
To show SyncE configuration, run the nv show synce
command:
cumulus@switch:~$ nv show synce
ADD OUTPUT
To show SyncE statistics for all the enabled interfaces, run the nv show synce interface statistics
command:
cumulus@switch:~$ nv show synce interface statistics
ADD OUTPUT
To show SyncE statistics for a specific interfaces, run the nv show synce interface statistics <interface>
command:
cumulus@switch:~$ nv show synce interface statistics swp2
ADD OUTPUT