System
nv show maintenance 
Show the current maintenance state of the switch.
Cumulus Linux 5.12 and earlier does not provide this command; run the nv show system maintenance command instead.
Version History
Introduced in Cumulus Linux 5.13.0
Example
cumulus@switch:~$ nv show maintenance 
Maintenance Info 
============== 
Unit                                 State 
-----------------------              --------------- 
all-protocols                        maintenance 
all-interfaces                       maintenance 
nv show maintenance unit all-protocols 
Shows the current maintenance state of the protocols.
Cumulus Linux 5.12 and earlier does not provide this command; run the nv show system maintenance unit all-protocols command instead.
Version History
Introduced in Cumulus Linux 5.13.0
Example
cumulus@switch:~$ nv show maintenance unit all-protocols
              operational      applied 
----------    -----------      ----------- 
state         maintenance       maintenance 
interfaces
protocols             all 
nv show system 
Shows information about the switch, such as the hostname, version information, the switch uptime, time zone, memory, and health status.
Version History
Introduced in Cumulus Linux 5.2.0
Example
cumulus@switch:~$ nv show system
uptime             1 day, 1:52:24                                                 
hostname           leaf01 
product-name       Cumulus Linux                                                  
platform           N/A                                                            
system-memory      1.31 GB used / 363.36 MB free / 1.67 GB total                  
swap-memory        0 Bytes used / 0 Bytes free / 0 Bytes total                    
health-status      Not OK                                                         
date-time          2025-04-18 12:48:46                                            
status             N/A                                                            
timezone           Etc/UTC                                                        
version                                                                           
  onie             N/A                                                            
  kernel           6.1.0-cl-1-amd64                                               
  base-os          Debian GNU/Linux 12.10                                         
Cumulus Linux 5.12 and earlier also shows build and product-release fields. NVUE removed these fields in Cumulus Linux 5.13.
nv show system cli 
Shows the current CLI settings. CLI settings include timeout and pager configuration.
Version History
Introduced in Cumulus Linux 5.9.0
Example
cumulus@switch:~$ nv show system cli
                  applied
----------------  -------
inactive-timeout  300  
pagination               
  state           enabled
  pager           more
nv show system cli pagination 
Shows if the pager is enabled and the configured pager settings (more, less, or vim.)
Version History
Introduced in Cumulus Linux 5.9.0
Example
cumulus@switch:~$ nv show system cli pagination
       applied
-----  -------
state  enabled
pager  more
nv show system counter 
Shows the polling interval for the switch counters for both the logical and physical interfaces.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system counter
                      applied
--------------------  -------
polling-interval             
  logical-interface   0:00:05
  physical-interface  0:00:02
nv show system counter rates 
Shows the load interval for the switch counters for both the logical and physical interfaces.
Version History
Introduced in Cumulus Linux 5.12.0
Example
cumulus@switch:~$ nv show system counter rates 
               applied
-------------  -------
load-interval  6
nv show system counter polling-interval 
Shows the polling interval for the switch counters for both the logical and physical interfaces.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system counter polling-interval
                   applied
------------------  -------
logical-interface   0:00:05
physical-interface  0:00:02
nv show system cpu 
Shows information about the switch CPU, such as the core-count, the model, and the utilization percentage.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system cpu
             operational                    applied
-----------  -----------------------------  -------
core-count   1                                     
model        QEMU Virtual CPU version 2.5+         
utilization  100.0%
nv show system date-time 
Shows the current date and time on the switch software clock.
In Cumulus Linux 5.7, 5.8, and 5.9, this command is nv show system time.
Version History
Introduced in Cumulus Linux 5.10.0
Example
cumulus@switch:~$ nv show system date-time
                           operational                  
-------------------------  -----------------------------
local-time                 Wed 2023-11-22 11:22:54 EST  
universal-time             Wed 2023-11-22 16:22:54 UTC  
rtc-time                   Wed 2023-11-22 16:22:54      
time-zone                  America/New_York (EST, -0500)
system-clock-synchronized  no                           
ntp-service                inactive                     
rtc-in-local-tz            no                           
unix-time                  1700670174.4371066
nv show system disk usage  
Shows disk utilization.
Version History
Introduced in Cumulus Linux 5.12.0
Example
cumulus@switch:~$ nv show system disk usage 
Mount Point  Filesystem  Size  Used  Avail  Use%
-----------  ----------  ----  ----  -----  ----
/            /dev/vda5   5.4G  2.5G  2.7G   49% 
/dev         udev        847M  0     847M   0%  
/dev/shm     tmpfs       856M  31M   825M   4%  
/run         tmpfs       172M  1.4M  170M   1%  
/run/lock    tmpfs       5.0M  0     5.0M   0%  
/tmp         tmpfs       856M  8.0K  856M   1% 
nv show system forwarding profile-option 
Shows forwarding profile information.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system forwarding profile-option
nv show system global 
Shows global system configuration, such as the anycast ID, anycast MAC address, fabric ID, fabric MAC address, system MAC address, routing table, VLAN, and VNI information.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global
                 operational        applied          
---------------  -----------------  -----------------
anycast-id       none               none             
anycast-mac      44:38:39:BE:EF:AA  44:38:39:BE:EF:AA
fabric-id        1                  1                
fabric-mac       none               none             
system-mac       44:38:39:22:01:7a  44:38:39:22:01:7a
l3svd                                                
  enable         off                off              
reserved                                             
  routing-table                                      
    pbr                                              
      begin      10000              10000            
      end        4294966272         4294966272       
  vlan                                               
    internal                                         
      range      3725-3999          3725-3999        
    l3-vni-vlan                                      
      begin      4000               4000             
      end        4064               4064
nv show system global reserved 
Shows global reserved configuration information, such as the VLAN internal range.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global reserved
               operational  applied   
-------------  -----------  ----------
routing-table                         
  pbr                                 
    begin      10000        10000     
    end        4294966272   4294966272
vlan                                  
  internal                            
    range      3725-3999    3725-3999 
  l3-vni-vlan                         
    begin      4000         4000      
    end        4064         4064
nv show system global reserved routing-table 
Shows global reserved routing table information.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global reserved routing-table
         operational  applied   
-------  -----------  ----------
pbr                             
  begin  10000        10000     
  end    4294966272   4294966272
nv show system global reserved vlan 
Shows the reserved VLAN configuration settings.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global reserved vlan
             operational  applied  
-----------  -----------  ---------
internal                           
  range      3725-3999    3725-3999
l3-vni-vlan                        
  begin      4000         4000     
  end        4064         4064
nv show system global reserved vlan internal 
Shows the reserved internal VLAN configuration settings.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global reserved vlan internal
       operational  applied  
-----  -----------  ---------
range  3725-3999    3725-3999
nv show system global reserved vlan l3-vni-vlan 
Shows the reserved VLAN layer 3 VNI to VLAN mapping settings.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system global reserved vlan l3-vni-vlan
       operational  applied
-----  -----------  -------
begin  4000         4000   
end    4064         4064
nv show system global  
Shows if the svi-force-up option is set to on for all SVIs on the switch.
The first time you configure a switch, all southbound bridge ports are down; therefore, by default, all SVIs are also down. You can force all SVIs to always be UP with the nv set system global svi-force-up enable on option, which is beneficial if you want to perform connectivity testing.
Version History
Introduced in Cumulus Linux 5.8.0
Example
nv show system global svi-force-up
       operational  applied
------  -----------  -------
enable  on           on
nv show system health 
Shows system health information.
Version History
Introduced in Cumulus Linux 5.10.0
Example
cumulus@switch:~$ nv show system health 
            operational  applied
----------  -----------  -------
status      OK                  
status-led  green               
Health issues
================
No Data
In 5.13 and later the nv show system health command output is:
nv show system health 
            operational  applied  
----------  -----------  -------
status      Not OK                       
status-led  amber                        
Health issues
================
    Component           Status information                                         
    ------------------  -----------------------------------------------------------
    ASIC                Not OK                                                     
    forwarding          active (running) since Wed 2025-04-23 17:44:13 UTC; 12h ago
    hw-management       inactive                                                   
    hw-management-sync  inactive                                                   
    hw-management-tc    inactive                                                   
    mft                 inactive                                                   
    process             Not OK
nv show system maintenance 
Show the current system maintenance mode.
Cumulus Linux 5.12 and earlier provides this command. For Cumulus Linux 5.13 and later use the nv show maintenance command instead.
Version History
Introduced in Cumulus Linux 5.7.0
Example
cumulus@switch:~$ nv show system maintenance 
       operational
-----  ----------- 
mode   disabled            
ports  enabled
nv show system memory 
Shows information about the switch memory, such as the total amount of memory, the amount of free and used memory, and the percent of memory utilized.
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv show system memory
Type      Buffers   Cache      Free       Total    Used       Utilization
--------  --------  ---------  ---------  -------  ---------  -----------
Physical  36.32 MB  521.31 MB  236.07 MB  1.69 GB  935.82 MB  86.4%      
Swap                           0 Bytes    0 Bytes  0 Bytes    0.0%
nv show system message 
Shows pre- and post-login messages.
Version History
Introduced in Cumulus Linux 5.2.0
Example
cumulus@switch:~$ nv show system message
nv show system reboot 
Shows system reboot information, such as the time when the switch rebooted, the reason for the reboot, and the restart mode (fast, warm, cold).
Version History
Introduced in Cumulus Linux 5.2.0
Example
cumulus@switch:~$ nv show system reboot
          operational                       applied
---------  --------------------------------  -------
reason                                              
  gentime  2023-04-26T15:47:34.033663+00:00         
  reason   Unknown                                  
  user     system/root                              
mode       cold                              cold
nv show system reboot history 
Shows the system reboot history.
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv show system reboot history
    gentime                           reason   user       
--  --------------------------------  -------  -----------
1   2023-04-26T15:47:34.033663+00:00  Unknown  system/root
2   2023-04-26T15:38:12.317900+00:00  Unknown  system/root
3   2023-04-26T15:38:09.769047+00:00  Unknown  system/root
4   2023-04-26T15:38:02.208193+00:00  Unknown  system/root
5   2023-04-25T01:30:36.145781+00:00  Unknown  system/root
6   2023-04-25T01:30:32.430332+00:00  Unknown  system/root
7   2023-04-25T01:30:22.843263+00:00  Unknown  system/root
8   2023-04-25T01:26:10.124076+00:00  Unknown  system/root
9   2023-04-25T01:26:06.517457+00:00  Unknown  system/root
10  2023-04-25T01:25:53.811710+00:00  Unknown  system/root
nv show system reboot reason 
Shows the reason why the switch rebooted.
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv show system reboot reason
        operational                       applied
-------  --------------------------------  -------
gentime  2023-04-26T15:47:34.033663+00:00         
reason   Unknown                                  
user     system/root
nv show system reboot required 
Shows if you need to reboot the switch after upgrade.
Version History
Introduced in Cumulus Linux 5.9.0
Example
cumulus@switch:~$ nv show system reboot required
yes
nv show system version 
Shows the version information, such as kernel version and the Cumulus Linux release number.
Version History
Introduced in Cumulus Linux 5.10.0
Example
cumulus@switch:~$ nv show system version
            operational                 
----------  ----------------------------
kernel      6.1.0-cl-1-amd64            
build-date  Mon Jul 29 04:57:52 UTC 2024
image       5.10.0.0021                 
onie        N/A