If you are using the current version of Cumulus NetQ, the content on this page may not be up to date. The current version of the documentation is available
here. If you are redirected to the main page of the user guide, then this page may have been renamed; please search for it there.
NVIDIA NetQ 4.4 Release Notes
Download all 4.4 release notes as .xls
4.4.1 Release Notes
Open Issues in 4.4.1
Issue ID |
Description |
Affects |
Fixed |
3739222
|
The opta-check command does not properly validate if the required 16 CPU cores are present on the system for NetQ. The command only presents an error if there are fewer than 8 CPU cores detected. |
4.2.0-4.8.0 |
4.9.0-4.12.0 |
3442456
|
When an event notification is resolved or acknowledged, the NetQ UI might display a duplicate event with the original notification content and timestamp. |
4.2.0-4.6.0 |
4.7.0-4.12.0 |
3438973
|
When you install NetQ onto your VM, the installation fails with the following messages:05:57:33.023618: master-node-installer: Installed Debian … [ FAILED ]————————————–ERROR: Failed to install the master node This is due to an expired key in the installation tarball. For assistance working around this issue, contact NVIDIA support. |
4.3.0-4.5.0 |
4.6.0-4.12.0 |
3395385
|
When you use NetQ LCM to upgrade a Cumulus Linux switch in an MLAG pair, the upgrade might fail. |
4.4.1-4.5.0 |
4.6.0-4.12.0 |
3360627
|
When the switch RoCE egress pool buffer limit is configured as unlimited, the maximum buffer usage for RoCE counters might display incorrect values in the NetQ UI. |
4.4.1-4.5.0 |
4.6.0-4.12.0 |
3305144
|
When you perform a netq trace between two hosts, the following message might be printed in the output even when the trace is successful:argument of type ‘NoneType’ is not iterable |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3303284
|
When you run the netq show opta-health command, it might fail and produce the following error:ERROR: Expecting value: line 1 column 1 (char 0) |
4.3.0-4.4.1 |
4.5.0-4.12.0 |
3290068
|
When you back up NetQ data with the backuprestore.sh script, the operation fails with the following log messages:Failed to clear all earlier snapshot for keyspace:master. Exiting!command terminated with exit code 1Failed to execute /opt/backuprestore/createbackup.sh script on cassandra pod Failed to proceed ahead with backup procedure. Exiting ! Contact NVIDIA support for assistance performing a backup. |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3266922
|
When a NetQ agent sends your NetQ server or OPTA an unexpectedly large number for switch interface counters, netq check and netq show commands might fail with the following message:local variable ‘url’ referenced before assignment |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3241664
|
When you start the netq-agent service, the WJH service is enabled by default. However, when you run the netq config show agent wjh command, the output might reflect the WJH service as disabled. |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3179145
|
The NetQ agent does not collect VLAN information from WJH data. This has been resolved, however when you upgrade to a NetQ version with the fix, historical WJH data will not be displayed in the UI. |
4.3.0-4.4.1 |
4.5.0-4.12.0 |
3015875
|
NetQ trace might report incomplete route information when there are multiple default routes in a VRF in the path between the source and destination. |
4.1.0-4.4.1 |
4.5.0-4.12.0 |
Fixed Issues in 4.4.1
Issue ID |
Description |
Affects |
4.4.0 Release Notes
Open Issues in 4.4.0
Issue ID |
Description |
Affects |
Fixed |
3739222
|
The opta-check command does not properly validate if the required 16 CPU cores are present on the system for NetQ. The command only presents an error if there are fewer than 8 CPU cores detected. |
4.2.0-4.8.0 |
4.9.0-4.12.0 |
3442456
|
When an event notification is resolved or acknowledged, the NetQ UI might display a duplicate event with the original notification content and timestamp. |
4.2.0-4.6.0 |
4.7.0-4.12.0 |
3438973
|
When you install NetQ onto your VM, the installation fails with the following messages:05:57:33.023618: master-node-installer: Installed Debian … [ FAILED ]————————————–ERROR: Failed to install the master node This is due to an expired key in the installation tarball. For assistance working around this issue, contact NVIDIA support. |
4.3.0-4.5.0 |
4.6.0-4.12.0 |
3305144
|
When you perform a netq trace between two hosts, the following message might be printed in the output even when the trace is successful:argument of type ‘NoneType’ is not iterable |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3303284
|
When you run the netq show opta-health command, it might fail and produce the following error:ERROR: Expecting value: line 1 column 1 (char 0) |
4.3.0-4.4.1 |
4.5.0-4.12.0 |
3290068
|
When you back up NetQ data with the backuprestore.sh script, the operation fails with the following log messages:Failed to clear all earlier snapshot for keyspace:master. Exiting!command terminated with exit code 1Failed to execute /opt/backuprestore/createbackup.sh script on cassandra pod Failed to proceed ahead with backup procedure. Exiting ! Contact NVIDIA support for assistance performing a backup. |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3266922
|
When a NetQ agent sends your NetQ server or OPTA an unexpectedly large number for switch interface counters, netq check and netq show commands might fail with the following message:local variable ‘url’ referenced before assignment |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3241664
|
When you start the netq-agent service, the WJH service is enabled by default. However, when you run the netq config show agent wjh command, the output might reflect the WJH service as disabled. |
4.4.0-4.4.1 |
4.5.0-4.12.0 |
3179145
|
The NetQ agent does not collect VLAN information from WJH data. This has been resolved, however when you upgrade to a NetQ version with the fix, historical WJH data will not be displayed in the UI. |
4.3.0-4.4.1 |
4.5.0-4.12.0 |
3015875
|
NetQ trace might report incomplete route information when there are multiple default routes in a VRF in the path between the source and destination. |
4.1.0-4.4.1 |
4.5.0-4.12.0 |
Fixed Issues in 4.4.0
Issue ID |
Description |
Affects |
3254224
|
In a What Just Happened table, column titles might appear as long strings of text. To fix this issue, select the ‘reset columns’ icon at the upper-right corner of the application. |
|
3244553
|
The What Just Happened (WJH) feature does not work with the NetQ agent on SONiC switches. |
|
3226405
|
TLS versions 1.0 and 1.1 are enabled for the OPTA API Gateway listening on TCP port 32708. Only TLS versions 1.2 and 1.3 should be enabled. |
4.3.0 |
3216161
|
In an OPTA clustered environment, NetQ agents might appear as rotten after upgrading to NetQ 4.3.0. To work around this issue, configure the spice: false parameter in /etc/netq/netq.yml . |
4.3.0 |
3211317
|
Upgrading Cumulus Linux with NetQ LCM fails when you upgrade a switch with the MLAG primary role. |
4.3.0 |
3205778
|
In some high scale environments, NetQ agents might appear as rotten during high load. |
4.3.0 |
3203960
|
When you add an LDAP user, the operation will fail and return an error: Parameter error . This has been resolved in NetQ 4.4.0 and later. If you configured LDAP authentication prior to NetQ 4.4.0, you must reconfigure LDAP after upgrading. |
|
3157803
|
The netq show commands to view MACs, IP addresses, neighbors, and routes might show a higher value compared to the corresponding entries in the NetQ UI. The netq show commands display additional values from the NetQ server or OPTA in addition to monitored devices in the NetQ inventory. |
4.2.0-4.3.0 |
3141723
|
When you edit a TCA rule, an error will prevent the rule from updating. To work around this problem, delete the existing rule and create a new one. |
|
3140425
|
LCM NetQ install or upgrade will silently fail if a target switch’s hostname is still set to the default (cumulus for Cumulus Linux or sonic} for SONiC). |
|
3131311
|
Sensor validation checks might still reflect a failure in NetQ after the sensor failure has recovered. |
4.2.0-4.3.0 |
3085064
|
When you attempt to install NetQ on a device using LCM and configure the incorrect VRF, the installation will be reflected as successful but the switch will not be present in the inventory in the LCM UI. |
4.1.0-4.3.0 |
3053143
|
The MLAG Session card might not show all MLAG events. |
4.2.0-4.3.0 |
2605545
|
Sort functionality is disabled when the number of records exceeds 10,000 entries in a full-screen, tabular view. |
4.3.0 |