NetQ provides the information you need to validate the health of your network fabric, devices, and interfaces. Whether you use the NetQ UI or the NetQ CLI to create and run validations, the underlying checks are the same. The number of checks and the type of checks are tailored to the particular protocol or element being validated.

NetQ Agent Validation Tests

NetQ Agent validation looks for an agent status of Rotten for each node in the network. A Fresh status indicates the Agent is running as expected. The Agent sends a heartbeat every 30 seconds, and if three consecutive heartbeats are missed, its status changes to Rotten. This is accomplished with the following test:

Test Number Test Name Description
0 Agent Health Checks for nodes that have failed or lost communication

BGP Validation Tests

The BGP validation tests look for indications of the session sanity (status and configuration). This is accomplished with the following tests:

Test Number Test Name Description
0 Session Establishment Checks that BGP sessions are in an established state
1 Address Families Checks if transmit and receive address family advertisement is consistent between peers of a BGP session
2 Router ID Checks for BGP router ID conflict in the network

CLAG Validation Tests

The CLAG validation tests look for misconfigurations, peering status, and bond error states. This is accomplished with the following tests:

Test Number Test Name Description
0 Peering Checks if:
  • CLAG peerlink is up
  • CLAG peerlink bond slaves are down (not in full capacity and redundancy)
  • Peering is established between two nodes in a CLAG pair
1 Backup IP Checks if:
  • CLAG backup IP configuration is missing on a CLAG node
  • CLAG backup IP is correctly pointing to the CLAG peer and its connectivity is available
2 Clag Sysmac Checks if:
  • CLAG Sysmac is consistently configured on both nodes in a CLAG pair
  • There is any duplication of a CLAG sysmac within a bridge domain
3 VXLAN Anycast IP Checks if the VXLAN anycast IP address is consistently configured on both nodes in a CLAG pair
4 Bridge Membership Checks if the CLAG peerlink is part of bridge
5 Spanning Tree Checks if:
  • STP is enabled and running on the CLAG nodes
  • CLAG peerlink role is correct from STP perspective
  • The bridge ID is consistent between two nodes of a CLAG pair
  • The VNI in the bridge has BPDU guard and BPDU filter enabled
6 Dual Home Checks for:
  • CLAG bonds that are not in dually connected state
  • Dually connected bonds have consistent VLAN and MTU configuration on both sides
  • STP has consistent view of bonds' dual connectedness
7 Single Home Checks for:
  • Singly connected bonds
  • STP has consistent view of bond’s single connectedness
8 Conflicted Bonds Checks for bonds in CLAG conflicted state and shows the reason
9 ProtoDown Bonds Checks for bonds in protodown state and shows the reason
10 SVI Checks if:
  • An SVI is configured on both sides of a CLAG pair
  • SVI on both sides have consistent MTU setting

Cumulus Linux Version Tests

The Cumulus Linux version tests looks for version consistency. This is accomplished with the following tests:

Test Number Test Name Description
0 Cumulus Linux Image Version Checks the following:
  • No version specified, checks that all switches in the network have consistent version
  • match-version specified, checks that a switch’s OS version is equals the specified version
  • min-version specified, checks that a switch’s OS version is equal to or greater than the specified version

EVPN Validation Tests

The EVPN validation tests look for indications of the session sanity and configuration consistency. This is accomplished with the following tests:

Test Number Test Name Description
0 EVPN BGP Session Checks if:
  • BGP EVPN sessions are established
  • The EVPN address family advertisement is consistent
1 EVPN VNI Type Consistency Because a VNI can be of type L2 or L3, checks that for a given VNI, its type is consistent across the network
2 EVPN Type 2 Checks for consistency of IP-MAC binding and the location of a given IP-MAC across all VTEPs
3 EVPN Type 3 Checks for consistency of replication group across all VTEPs
4 EVPN Session For each EVPN session, checks if:
  • adv_all_vni is enabled
  • FDB learning is disabled on tunnel interface
5 Vlan Consistency Checks for consistency of VLAN to VNI mapping across the network
6 Vrf Consistency Checks for consistency of VRF to L3 VNI mapping across the network

Interface Validation Tests

The interface validation tests look for consistent configuration between two nodes. This is accomplished with the following tests:

Test Number Test Name Description
0 Admin State Checks for consistency of administrative state on two sides of a physical interface
1 Oper State Checks for consistency of operational state on two sides of a physical interface
2 Speed Checks for consistency of the speed setting on two sides of a physical interface
3 Autoneg Checks for consistency of the auto-negotiation setting on two sides of a physical interface

License Validation Tests

The license validation test looks for a valid Cumulus Linux license on all switches. This is accomplished with the following test:

Test Number Test Name Description
0 License Validity Checks for validity of license on all switches

The link MTU validation tests look for consistency across an interface and appropriate size MTU for VLAN and bridge interfaces. This is accomplished with the following tests:

Test Number Test Name Description
0 Link MTU Consistency Checks for consistency of MTU setting on two sides of a physical interface
1 VLAN interface Checks if the MTU of an SVI is no smaller than the parent interface, substracting the VLAN tag size
2 Bridge interface Checks if the MTU on a bridge is not arbitrarily smaller than the smallest MTU among its members

MLAG Validation Tests

The MLAG validation tests look for misconfigurations, peering status, and bond error states. This is accomplished with the following tests:

Test Number Test Name Description
0 Peering Checks if:
  • MLAG peerlink is up
  • MLAG peerlink bond slaves are down (not in full capacity and redundancy)
  • Peering is established between two nodes in a MLAG pair
1 Backup IP Checks if:
  • MLAG backup IP configuration is missing on a MLAG node
  • MLAG backup IP is correctly pointing to the MLAG peer and its connectivity is available
2 Clag Sysmac Checks if:
  • MLAG Sysmac is consistently configured on both nodes in a MLAG pair
  • There is any duplication of a MLAG sysmac within a bridge domain
3 VXLAN Anycast IP Checks if the VXLAN anycast IP address is consistently configured on both nodes in an MLAG pair
4 Bridge Membership Checks if the MLAG peerlink is part of bridge
5 Spanning Tree Checks if:
  • STP is enabled and running on the MLAG nodes
  • MLAG peerlink role is correct from STP perspective
  • The bridge ID is consistent between two nodes of a MLAG pair
  • The VNI in the bridge has BPDU guard and BPDU filter enabled
6 Dual Home Checks for:
  • MLAG bonds that are not in dually connected state
  • Dually connected bonds have consistent VLAN and MTU configuration on both sides
  • STP has consistent view of bonds' dual connectedness
7 Single Home Checks for:
  • Singly connected bonds
  • STP has consistent view of bond’s single connectedness
8 Conflicted Bonds Checks for bonds in MLAG conflicted state and shows the reason
9 ProtoDown Bonds Checks for bonds in protodown state and shows the reason
10 SVI Checks if:
  • An SVI is configured on both sides of a MLAG pair
  • SVI on both sides have consistent MTU setting

NTP Validation Tests

The NTP validation test looks for poor operational status of the NTP service. This is accomplished with the following test:

Test Number Test Name Description
0 NTP Sync Checks if the NTP service is running and in sync state

OSPF Validation Tests

The EVPN validation tests look for indications of the service health and configuration consistency. This is accomplished with the following tests:

Test Number Test Name Description
0 Router ID Checks for OSPF router ID conflicts in the network
1 Adjacency Checks or OSPF adjacencies in a down or unknown state
2 Timers Checks for consistency of OSPF timer values in an OSPF adjacency
3 Network Type Checks for consistency of network type configuration in an OSPF adjacency
4 Area ID Checks for consistency of area ID configuration in an OSPF adjacency
5 Interface MTU Checks for MTU consistency in an OSPF adjacency
6 Service Status Checks for OSPF service health in an OSPF adjacency

Sensor Validation Tests

The sensor validation tests looks for chassis power supply, fan, and temperature sensors that are in a bad state. This is accomplished with the following tests:

Test Number Test Name Description
0 PSU sensors Checks for power supply unit sensors that are not in ok state
1 Fan sensors Checks for fan sensors that are not in ok state
2 Temperature sensors Checks for temperature sensors that are not in ok state

VLAN Validation Tests

The VLAN validation tests look for configuration consistency between two nodes. This is accomplished with the following tests:

Test Number Test Name Description
0 Link Neighbor VLAN Consistency Checks for consistency of VLAN configuration on two sides of a port or a bond
1 CLAG Bond VLAN Consistency Checks for consistent VLAN membership of a CLAG (MLAG) bond on each side of the CLAG (MLAG) pair

VXLAN Validation Tests

The VXLAN validation tests look for configuration consistency across all VTEPs. This is accomplished with the following tests:

Test Number Test Name Description
0 VLAN Consistency Checks for consistent VLAN to VXLAN mapping across all VTEPs
1 BUM replication Checks for consistent replication group membership across all VTEPs